Comparisons

Hybrid vs Off-grid Inverter: Which to Source

When to source a hybrid inverter versus an off-grid unit, with real specs, use cases, parallel scaling, and an RFQ checklist.

Hybrid vs Off-grid Inverter: Which to Source

What to decide before asking for price.

Hybrid vs Off-grid Inverter: Which to Source

  • Does the site have a grid connection, and is it stable enough to serve as a reference voltage for a grid-tied inverter?
  • What is the local grid standard, AC output requirement, and export permission for this market? A hybrid must match the grid; an off-grid unit must deliver the right AC output for the loads.
  • What battery voltage and chemistry is planned or on site? The R-G2 hybrid line is 40 to 58V LiFePO4; the SPIRE 3500-24 needs 24VDC and the SPIRE 5500-48 needs 48VDC. A mismatch here is not recoverable without replacing equipment.
OptionBest fitWhat to confirm
Hybrid inverterConnects grid, battery, and solar at once: self-consume solar, charge the battery with surplus, draw from the grid when needed, and export where the local standard allows. R-G2 single-phase line runs 3kW to 8kW, 40 to 58V battery, up to 12kW PV on the R8KL1-G2, 98.2% max efficiency, IP65.Best when the customer has a reliable grid and wants lower bills through self-consumption, outage backup, or time-of-use shifting. The dominant residential and light-commercial export demand.
Off-grid inverterOperates with no grid connection. The SPIRE series combines a pure sine wave inverter, MPPT charger (120 to 450VDC, 100A), and AC charger in one unit. SPIRE 3500-24: 3500W, 24VDC, 7000VA surge, up to 5000W PV. SPIRE 5500-48: 5500W, 48VDC, 11000VA surge, up to 6000W PV. Up to six units parallel for 33kW.Best when there is no grid access or a grid too unreliable to serve as a reference voltage: cabins, rural homes, telecom shelters, islands, remote commercial sites.
Buyer decisionAsk first: does the site have a stable grid connection? If yes, a hybrid inverter is almost always the right start. If no, the off-grid unit is correct.Then sharpen with grid standard and export permission, battery voltage on site (24V, 48V, or 40 to 58V LiFePO4), total load and surge demand, and phased expansion. Confirm any specific grid interconnection requirement with sales.

제품

Products to shortlist

R5KL1-G2 Hybrid Inverter

태양광 인버터 / G2 Single-phase Hybrid Inverter

R5KL1-G2 Hybrid Inverter

R5KL1-G2 Hybrid Inverter은 태양광 인버터 제품군입니다. B2B 조달, 설치 채널에 적합합니다. 주요 사양: Start voltage: 100V; 최대 PV 전압: 500V. 가격은 수량과 요구사항에 따라 확인됩니다.

Start voltage100V최대 PV 전압500V배터리 전압40-58V
R8KL1-G2 Hybrid Inverter

태양광 인버터 / G2 Single-phase Hybrid Inverter

R8KL1-G2 Hybrid Inverter

R8KL1-G2 Hybrid Inverter은 태양광 인버터 제품군입니다. B2B 조달, 설치 채널에 적합합니다. 주요 사양: Start voltage: 100V; 최대 PV 전압: 500V. 가격은 수량과 요구사항에 따라 확인됩니다.

Start voltage100V최대 PV 전압500V배터리 전압40-58V
SPIRE 3500-24 Off-grid Inverter

태양광 인버터 / SPIRE Off-grid Inverter

SPIRE 3500-24 Off-grid Inverter

SPIRE 3500-24 Off-grid Inverter은 태양광 인버터 제품군입니다. B2B 조달, 설치 채널에 적합합니다. 주요 사양: 파형: 순수 정현파; 피크 효율: >93.6%. 가격은 수량과 요구사항에 따라 확인됩니다.

파형순수 정현파피크 효율>93.6%전환 시간10ms
SPIRE 5500-48 Off-grid Inverter

태양광 인버터 / SPIRE Off-grid Inverter

SPIRE 5500-48 Off-grid Inverter

SPIRE 5500-48 Off-grid Inverter은 태양광 인버터 제품군입니다. B2B 조달, 설치 채널에 적합합니다. 주요 사양: 파형: 순수 정현파; 피크 효율: >93.6%. 가격은 수량과 요구사항에 따라 확인됩니다.

파형순수 정현파피크 효율>93.6%전환 시간10ms

소싱 어시스턴트

적합한 Spire ESS 솔루션 찾기

B2B 빠른 응답
프로젝트 요구사항을 공유해 주시면 용도, 용량, 모델 매칭을 도와드립니다.